Intelligent (Addressable) Fire Alarm

Advanced addressable systems for complex facilities — scalable control panels, loop devices, special detection (VESDA, beam, linear heat), and integration-ready modules.

Control Panels

Addressable Fire Alarm Control Panel — 1 loop

Typical model: NFS-320

Compact addressable FACP for small/medium sites; supports loop devices, event logic, and networking.

Addressable Fire Alarm Control Panel — 3/5/6/7/8/9/10 loops

Typical model: NFS2-640

Mid-range scalable panel for multi-zone facilities; networking & graphical supervision ready.

High-capacity Addressable Fire Alarm Control Panel

Typical model: NFS2-3030

Large/complex campuses — extensive loops, integration gateways, and advanced cause-and-effect.

Graphic Monitoring Software

Typical product: ONYXWORKS® Station

Centralized graphical supervision, event logging, and remote control for networked fire systems.

Field Detectors

Addressable Smoke Detector

Typical model: FSP-951

Photoelectric addressable detector with drift compensation and maintenance alerts.

Addressable Heat Detector

Typical model: FST-951R

Rate-of-rise / fixed-temperature options for harsh or dusty environments.

Addressable Multi-sensor (Smoke/Heat/IR)

Typical model: FAPT-951

Multi-criteria detection for reduced false alarms and faster response.

Duct Smoke Detector

Typical model: DNR

Sampling tube housing for HVAC ducts to shut down fans and prevent smoke spread.

Special Detection

Aspirating Early Warning (VESDA)

Typical model: VESDA

Very early warning smoke detection for data centers, clean rooms, and high-airflow spaces.

Addressable Beam Detector

Typical model: FSB-200

Long-range open-area smoke detection for large halls and atriums.

Linear Heat Detection Cable

Typical model: PHSC-135EPC

Continuous temperature-sensing cable for tunnels, conveyors, cable trays and harsh areas.

Manual Stations

Addressable Manual Pull Station

Typical model: NBG-12LX

Dual-action pull station for indoor applications; addressable module built-in.

Outdoor / Weather-Proof Manual Station

Typical model: NBG-12LOB (WP)

Rugged enclosure for outdoor and harsh environments; maintained performance in rain/dust.

Modules

Fault Isolator Module

Model: ISO-X

Protects SLC loops by isolating short-circuit segments to maintain system operation.

Control Module

Model: FCM-1

Supervised control output for releasing devices, fans, dampers, or door holders.

Relay Module

Model: FRM-1

Programmable dry contacts for integration with third-party systems (BMS, ATS, lifts…).

Monitor Module

Model: FMM-1